Bar Manifolds
ISOLATION PORT CODES
When isolations are required in the pressure or tank ports for any Bar Manifold, the final two letters in the part number need to be modified as per the chart below. The second last character identifies the pressure port isolation and the last character identifies the tank port isolations.
For Example:
- BA03GPS04SDUAAAA is a Four Station Standard Flow D03 Parallel Circuit Manifold with SAE Ports, no isolations and no Relief Cavity
- BA03GPS04SDUCAAA is as 1) with Sun T-10A Relief Cavity Option
- BA03GPS04SDUCACA is as 2) with Pressure Port Isolation only between Stations 2 & 3 of this Four Station Manifold. The Relief Cavity is left of the isolation as viewed from the A & B working ports.
- BA03GPS04SDUCATT is as 2) with Pressure and Tank Port Isolations between Stations 3 & 4, and Two Sun T-10A Relief Cavities, one on each side of the isolations.
- BA03GPS04SDUAACB is as 1) with Pressure Port Isolation between Stations 2 & 3 and Tank Port Isolation between Stations 1 & 2.
Isolation Location |
CODE |
Relief Location |
CODE |
Relief Location |
CODE |
Relief Location |
| None |
A |
Standard |
|
|
|
|
| 01 - 02 |
B |
Left or None |
J |
Right |
R |
Both Sides |
| 02 - 03 |
C |
Left or None |
K |
Right |
S |
Both Sides |
| 03 -04 |
D |
Left or None |
L |
Right |
T |
Both Sides |
| 04 - 05 |
E |
Left or None |
M |
Right |
U |
Both Sides |
| 05 - 06 |
F |
Left or None |
N |
Right |
V |
Both Sides |
| 06 - 07 |
G |
Left or None |
O |
Right |
W |
Both Sides |
| 07 - 08 |
H |
Left or None |
P |
Right |
X |
Both Sides |
| 08 - 09 |
I |
Left or None |
Q |
Right |
Y |
Both Sides |
| 09 - 10 |
2 |
Left or None |
5 |
Right |
Z |
Both Sides |
| 10 - 11 |
3 |
Left or None |
6 |
Right |
8 |
Both Sides |
| 11 - 12 |
4 |
Left or None |
7 |
Right |
9 |
Both Sides |
Note: