1.00.02
5/2010.A
Isolation Codes

Bar Manifolds

ISOLATION PORT CODES
When isolations are required in the pressure or tank ports for any Bar Manifold, the final two letters in the part number need to be modified as per the chart below. The second last character identifies the pressure port isolation and the last character identifies the tank port isolations.

For Example:

  1. BA03GPS04SDUAAAA is a Four Station Standard Flow D03 Parallel Circuit Manifold with SAE Ports, no isolations and no Relief Cavity
  2. BA03GPS04SDUCAAA is as 1) with Sun T-10A Relief Cavity Option
  3. BA03GPS04SDUCACA is as 2) with Pressure Port Isolation only between Stations 2 & 3 of this Four Station Manifold. The Relief Cavity is left of the isolation as viewed from the A & B working ports.
  4. BA03GPS04SDUCATT is as 2) with Pressure and Tank Port Isolations between Stations 3 & 4, and Two Sun T-10A Relief Cavities, one on each side of the isolations.
  5. BA03GPS04SDUAACB is as 1) with Pressure Port Isolation between Stations 2 & 3 and Tank Port Isolation between Stations 1 & 2.

Isolation
Location
CODE Relief
Location
CODE Relief
Location
CODE Relief
Location
None A Standard        
01 - 02 B Left or None J Right R Both Sides
02 - 03 C Left or None K Right S Both Sides
03 -04 D Left or None L Right T Both Sides
04 - 05 E Left or None M Right U Both Sides
05 - 06 F Left or None N Right V Both Sides
06 - 07 G Left or None O Right W Both Sides
07 - 08 H Left or None P Right X Both Sides
08 - 09 I Left or None Q Right Y Both Sides
09 - 10 2 Left or None 5 Right Z Both Sides
10 - 11 3 Left or None 6 Right 8 Both Sides
11 - 12 4 Left or None 7 Right 9 Both Sides

Note:
All Part Number combinations may not be possible. Please consult the factory to confirm your application requirements.